mniꯂꯣꯜ

ꯀꯟꯗꯦꯟꯁꯔ ꯑꯃꯁꯨꯡ ꯏꯚꯥꯛꯌꯨꯑꯦꯇꯔꯁꯤꯡꯗꯥ ꯑꯃꯥꯡ-ꯑꯇꯥ ꯊꯣꯀꯍꯅꯕꯒꯤ ꯃꯇꯥꯡꯗꯥ ꯋꯥꯌꯦꯜ ꯄꯤꯅꯕꯒꯤ ꯄꯥꯝꯕꯩꯁꯤꯡ꯫

Jul 03, 2026

ꯄꯥꯎꯖꯦꯜ ꯑꯃꯥ ꯊꯥꯗꯣꯀꯎ

 

Water Consumption of Closed-Loop Cooling Systemsꯀꯟꯗꯦꯟꯁꯔ ꯑꯃꯁꯨꯡ ꯏꯚꯥꯛꯌꯨꯑꯦꯇꯔꯁꯤꯡ ꯑꯁꯤ ꯔꯦꯐ꯭ꯔꯤꯖꯔꯦꯁꯟ ꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡꯒꯤ ꯃꯔꯨꯑꯣꯏꯕꯥ ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖ ꯀꯝꯄꯣꯅꯦꯟꯇ ꯑꯅꯤꯅꯤ꯫

 

ꯂꯤꯛ, ꯕ꯭ꯂꯣꯀꯦꯖ, ꯗꯤꯐꯣꯔꯃꯦꯁꯟ ꯅꯠꯠꯔꯒꯥ ꯀꯣꯔꯣꯁꯤꯅꯅꯥ ꯁꯣꯀꯍꯜꯂꯕꯥ ꯃꯇꯨꯡꯗꯥ, ꯃꯈꯣꯌꯅꯥ ꯀꯨꯂꯤꯡ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯐꯠꯇꯕꯥ, ꯑꯦꯕꯅꯣꯔꯃꯦꯜ ꯄ꯭ꯔꯦꯁꯔ ꯑꯃꯁꯨꯡ ꯌꯨꯅꯤꯠ ꯑꯦꯂꯥꯔꯃꯁꯤꯡꯒꯨꯝꯕꯥ ꯐꯂꯁꯤꯡ ꯍꯀꯊꯦꯡꯅꯅꯥ ꯊꯣꯀꯍꯜꯂꯛꯀꯅꯤ꯫

 

ꯑꯄꯨꯅꯕꯥ ꯋꯥꯔꯦꯞ ꯃꯔꯤ ꯑꯁꯤ ꯑꯦꯞꯔꯣꯆ ꯃꯔꯤꯒꯤ ꯈꯨꯠꯊꯥꯡꯗꯥ ꯄꯥꯡꯊꯣꯀꯄꯥ ꯌꯥꯏ: ꯚꯤꯖꯨꯑꯦꯜ ꯏꯟꯁꯄꯦꯛꯁꯟ, ꯑꯣꯄꯔꯦꯇꯤꯡ ꯄꯦꯔꯥꯃꯤꯇꯔ ꯗꯤꯇꯦꯛꯇꯦꯁꯟ, ꯁꯦꯛꯁꯟ ꯄ꯭ꯔꯦꯁꯔ ꯇꯦꯁ꯭ꯠ ꯑꯃꯁꯨꯡ ꯁꯤꯁ꯭ꯇꯦꯃꯒꯤ ꯊꯕꯛ ꯇꯧꯕꯒꯤ ꯀꯟꯗꯤꯁꯟ ꯆꯥꯡꯗꯝꯅꯕꯥ, ꯃꯄꯨꯡ ꯐꯥꯅꯥ ꯑꯃꯥꯡ-ꯑꯇꯥꯁꯤꯡꯗꯒꯤ ꯑꯄꯤꯀꯄꯥ ꯑꯁꯣꯏꯕꯁꯤꯡ ꯈꯦꯠꯅꯕꯥ ꯊꯝꯅꯕꯥ꯫

 

 

I. ꯎꯕꯥ ꯐꯪꯂꯤꯕꯥ ꯑꯃꯥꯡ-ꯑꯇꯥꯁꯤꯡ ꯌꯥꯝꯅꯥ ꯊꯨꯅꯥ ꯈꯉꯗꯣꯛꯅꯕꯥ ꯄ꯭ꯔꯤꯂꯤꯃꯤꯅꯥꯔꯤ ꯚꯤꯖꯨꯑꯦꯜ ꯏꯟꯁꯄꯦꯛꯁꯟ꯫

 

Applicable Industries and Application Advantages of Closed Cooling Towersꯃꯄꯥꯟꯊꯪꯕꯥ ꯁꯔꯨꯛ ꯑꯗꯨ ꯌꯦꯡꯗ꯭ꯔꯤꯉꯩꯗꯥ ꯄꯥꯋꯔ ꯀꯀꯊꯠꯂꯨ ꯑꯃꯁꯨꯡ ꯌꯨꯅꯤꯠ ꯑꯗꯨ ꯊꯤꯡꯖꯤꯜꯂꯨ, ꯃꯐꯃꯗꯨꯗꯥ ꯑꯌꯥꯝꯕꯥ ꯔꯤꯚꯔꯁꯤꯕꯜ ꯑꯣꯏꯕꯥ ꯑꯃꯥꯡ-ꯑꯇꯥꯁꯤꯡ ꯑꯁꯤ ꯃꯤꯠꯅꯥ ꯎꯕꯥ ꯐꯪꯏ꯫ ꯑꯍꯥꯅꯕꯗꯥ, ꯄꯥꯏꯄꯂꯥꯏꯟ ꯑꯃꯁꯨꯡ ꯁꯦꯂꯁꯤꯡꯗꯥ ꯀꯣꯔꯣꯁꯤꯟ ꯆꯦꯛꯁꯤꯟꯅꯥ ꯌꯦꯡꯎ꯫

 

ꯏꯁꯤꯡ-ꯀꯨꯜ ꯇꯧꯔꯕꯥ ꯀꯟꯗꯦꯟꯁꯔꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯀ꯭ꯂꯣꯖꯗ ꯏꯚꯥꯄꯣꯔꯦꯇꯔꯁꯤꯡꯒꯤ ꯀꯣꯏꯂꯁꯤꯡ ꯑꯁꯤ ꯃꯇꯝ ꯁꯥꯡꯅꯥ ꯊꯕꯛ ꯇꯧꯅꯕꯒꯤꯗꯃꯛ ꯏꯁꯤꯡꯒꯤ ꯃꯤꯗꯤꯌꯥꯗꯥ ꯊꯃꯖꯤꯜꯂꯤ꯫ꯅꯨꯡꯒꯤ ꯑꯣꯏꯕꯥ ꯋꯥꯂꯁꯤꯡꯗꯥ ꯁ꯭ꯀꯦꯜ ꯇꯧꯕꯥ ꯑꯃꯁꯨꯡ ꯃꯄꯥꯅꯒꯤ ꯋꯥꯂꯁꯤꯡꯗꯥ ꯑꯦꯁꯤꯗ-ꯕꯦꯖ ꯀꯣꯔꯣꯁꯤꯅꯅꯥ ꯃꯩꯁꯥꯒꯤ ꯃꯐꯃꯁꯤꯡ, ꯄꯣꯔꯐꯣꯔꯦꯁꯟ ꯑꯃꯁꯨꯡ ꯏꯁꯤꯡ ꯇꯨꯡꯁꯤꯅꯕꯒꯤ ꯃꯁꯀꯁꯤꯡ ꯁꯦꯃꯒꯅꯤ꯫

 

ꯐ꯭ꯔꯤꯑꯣꯟ ꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡꯗꯥ ꯑꯃꯥꯡ-ꯑꯇꯥ ꯊꯣꯀꯄꯥ ꯀꯣꯏꯂꯁꯤꯡꯅꯥ ꯑꯣꯏꯜ ꯁ꯭ꯇꯦꯅꯁꯤꯡ ꯊꯃꯒꯅꯤ, ꯃꯔꯃꯗꯤ ꯔꯦꯐ꯭ꯔꯤꯖꯔꯦꯟꯇ ꯑꯁꯤ ꯔꯦꯐ꯭ꯔꯤꯖꯔꯦꯁꯟ ꯑꯣꯏꯂꯒꯥ ꯂꯣꯌꯅꯅꯥ ꯂꯤꯛ ꯇꯧꯏ, ꯑꯃꯁꯨꯡ ꯑꯣꯏꯜ ꯑꯦꯛꯌꯨꯃꯨꯂꯦꯁꯅꯒꯤ ꯃꯥꯔꯀꯁꯤꯡꯅꯥ ꯂꯤꯛ ꯄꯣꯏꯟꯇꯁꯤꯡ ꯄꯤꯅꯄꯣꯏꯟꯇ ꯇꯧꯏ꯫ ꯀꯔꯤꯒꯨꯝꯕꯥ ꯑꯦꯌꯔ-ꯀꯨꯜ ꯇꯧꯔꯕꯥ ꯀꯟꯗꯦꯟꯁꯔ ꯑꯃꯁꯨꯡ ꯏꯚꯥꯛꯌꯨꯑꯦꯇꯔꯁꯤꯡꯒꯤ ꯐꯤꯅꯁꯤꯡ ꯑꯁꯤ ꯑꯆꯧꯕꯥ ꯃꯑꯣꯡꯗꯥ ꯀꯨꯄꯁꯤꯜꯂꯕꯥ ꯅꯠꯠꯔꯒꯥ ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖ ꯆꯦꯅꯦꯂꯁꯤꯡ ꯕ꯭ꯂꯣꯛ ꯇꯧꯅꯕꯥ ꯑꯦꯛꯁꯠꯔꯨꯗ ꯇꯧꯔꯕꯗꯤ, ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖ ꯐꯉ꯭ꯀꯁꯟ ꯑꯁꯤ ꯁꯣꯀꯍꯜꯂꯤ, ꯃꯁꯤꯅꯥ ꯐꯉ꯭ꯀꯁꯅꯦꯜ ꯗꯦꯃꯦꯖ ꯑꯣꯏꯅꯥ ꯀꯥꯎꯟꯇ ꯇꯧꯏ꯫

 

 

How Evaporative Condensers Workꯑꯅꯤꯁꯨꯕꯗꯥ, ꯋꯦꯜꯗꯤꯡ ꯖꯣꯅꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯇꯨꯕ ꯑꯦꯛꯁꯄꯥꯟꯁꯅꯒꯤ ꯄꯣꯖꯤꯁꯅꯁꯤꯡ ꯌꯦꯡꯁꯤꯜꯂꯨ꯫ ꯀꯣꯜꯗ ꯑꯃꯁꯨꯡ ꯍꯤꯠ ꯑꯣꯂꯇꯔꯅꯦꯇꯤꯚ ꯑꯣꯏꯅꯥ ꯐꯖꯅꯥ ꯄꯥꯀꯊꯣꯛ-ꯆꯥꯎꯊꯣꯛꯂꯕꯥ ꯖꯣꯅꯁꯤꯡꯗꯥ ꯀ꯭ꯔꯦꯛ ꯊꯣꯀꯍꯜꯂꯤ, ꯃꯗꯨꯅꯥ ꯏꯁꯤꯡ ꯇꯨꯡꯁꯤꯅꯕꯥ ꯑꯃꯁꯨꯡ ꯔꯦꯐ꯭ꯔꯤꯖꯔꯦꯟꯇ ꯂꯤꯛ ꯑꯣꯏꯕꯥ ꯊꯣꯀꯍꯜꯂꯤ꯫

 

ꯄ꯭ꯂꯦꯠ ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖꯔꯁꯤꯡꯒꯤ ꯕꯜꯕ ꯅꯠꯠꯔꯒꯥ ꯗꯤꯐꯣꯔꯃꯦꯁꯟ ꯄ꯭ꯂꯦꯇꯁꯤꯡꯅꯥ ꯏꯟꯇꯔꯅꯦꯜ ꯄ꯭ꯔꯦꯁꯔ ꯌꯥꯝꯅꯥ ꯋꯥꯡꯕꯅꯥ ꯃꯔꯝ ꯑꯣꯏꯗꯨꯅꯥ ꯄ꯭ꯂꯦꯠ ꯔꯄꯆꯔ ꯇꯧꯕꯥ ꯇꯥꯀꯏ꯫

 

ꯀꯔꯤꯒꯨꯝꯕꯥ ꯚꯜꯌꯨꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯄꯥꯏꯄꯀꯤ ꯖꯣꯅꯁꯤꯡꯒꯤ ꯑꯁꯣꯛ-ꯑꯄꯅꯁꯤꯡ ꯂꯧꯊꯣꯛꯂꯕꯥ ꯃꯇꯨꯡꯗꯥ ꯌꯨꯅꯤꯠ ꯑꯗꯨꯒꯤ ꯃꯈꯥꯗꯥ ꯃꯇꯝ ꯁꯥꯡꯅꯥ ꯏꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯏꯁꯤꯡ ꯊꯨꯃꯖꯤꯜꯂꯕꯗꯤ, ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖꯔꯒꯤ ꯍꯀꯆꯥꯡ ꯑꯗꯨ ꯃꯔꯨꯑꯣꯏꯅꯥ ꯁꯣꯀꯍꯜꯂꯤ꯫ ꯃꯁꯤꯒꯤ ꯃꯊꯛꯇꯥ, ꯊꯔꯃꯦꯜ ꯏꯅꯁꯨꯂꯦꯁꯟ ꯂꯦꯌꯔ ꯑꯗꯨ ꯆꯦꯛ ꯇꯧ: ꯁꯦꯡꯗꯣꯛꯂꯕꯥ ꯃꯇꯨꯡꯗꯥ ꯊꯨꯅꯥ ꯑꯃꯨꯛ ꯍꯟꯅꯥ ꯂꯥꯀꯄꯥ ꯏꯚꯥꯛꯌꯨꯑꯦꯇꯔꯁꯤꯡꯗꯥ ꯆꯦꯟꯊꯔꯀꯄꯥ, ꯁꯣꯀꯍꯜꯂꯕꯥ ꯏꯅꯁꯨꯂꯦꯁꯟ ꯑꯗꯨꯅꯥ ꯑꯌꯥꯝꯕꯅꯥ ꯃꯅꯨꯡꯒꯤ ꯑꯣꯏꯕꯥ ꯄꯥꯏꯄꯂꯥꯏꯟ ꯕ꯭ꯂꯣꯀꯦꯖ ꯅꯠꯠꯔꯒꯥ ꯄꯥꯔꯁꯤꯑꯦꯜ ꯂꯤꯛ ꯑꯣꯏꯕꯥ ꯌꯥꯏ꯫

 

 

II. ꯍꯤꯠ ꯇ꯭ꯔꯥꯟꯁꯐꯔ ꯄꯔꯐꯣꯃꯦꯟꯁ ꯗꯤꯒ꯭ꯔꯦꯗꯦꯁꯟ ꯖꯖ ꯇꯧꯅꯕꯥ ꯑꯣꯄꯔꯦꯇꯤꯡ ꯄꯦꯔꯥꯃꯤꯇꯔ ꯗꯤꯇꯦꯛꯁꯟ꯫

 

 

Converting From Open To Closed-Circuit Cooling Tower: How Much Can You Save in A Year? Real Data Tells You!

 

 

ꯌꯨꯅꯤꯠ ꯑꯗꯨ ꯃꯄꯨꯡꯐꯥꯅꯥ ꯂꯣꯗ ꯇꯧꯗꯨꯅꯥ ꯆꯠꯊꯕꯥ, ꯍꯥꯏ/ꯂꯣ ꯄ꯭ꯔꯦꯁꯔ, ꯏꯅꯂꯦꯠ ꯑꯃꯁꯨꯡ ꯑꯥꯎꯇꯂꯦꯠ ꯏꯁꯤꯡꯒꯤ ꯇꯦꯝꯄꯦꯔꯦꯆꯔ, ꯐꯦꯅꯁꯤꯡ/ ꯏꯁꯤꯡꯒꯤ ꯄꯝꯄꯁꯤꯡꯒꯤ ꯇꯦꯝꯄꯦꯔꯦꯆꯔꯒꯤ ꯈꯦꯠꯅꯕꯥ ꯑꯃꯁꯨꯡ ꯀꯔꯦꯟꯇ ꯔꯦꯀꯣꯔꯗ ꯇꯧꯕꯥ, ꯑꯃꯁꯨꯡ ꯑꯃꯥꯡ-ꯑꯇꯥꯒꯤ ꯆꯥꯡ ꯑꯗꯨ ꯏꯚꯥꯜꯌꯨꯑꯦꯠ ꯇꯧꯅꯕꯥ ꯔꯦꯠ ꯇꯧꯔꯕꯥ ꯄꯦꯔꯥꯃꯤꯇꯔꯁꯤꯡꯒꯥ ꯆꯥꯡꯗꯝꯅꯕꯥ꯫

 

ꯀꯟꯗꯦꯟꯁꯔꯁꯤꯡꯒꯤ ꯐꯣꯜꯇ ꯃꯑꯣꯡ-ꯃꯇꯧꯁꯤꯡ꯫

 

Closed-Circuit Cooling Tower Market Share Rose 7% in 5 Years – What's Behind It?ꯏꯁꯤꯡ-ꯀꯨꯜ ꯇꯧꯔꯕꯥ ꯀꯟꯗꯦꯟꯁꯔꯁꯤꯡꯒꯤ ꯑꯣꯏꯅꯗꯤ, ꯏꯅꯂꯦꯠ ꯑꯃꯁꯨꯡ ꯑꯥꯎꯇꯂꯦꯠ ꯏꯁꯤꯡꯒꯤ ꯃꯔꯛꯇꯥ ꯂꯩꯕꯥ ꯇꯦꯝꯄꯦꯔꯦꯆꯔꯒꯤ ꯈꯦꯠꯅꯕꯥ ꯑꯁꯤ ꯁ꯭ꯇꯦꯟꯗꯔꯗ 5 ꯗꯤꯒ꯭ꯔꯤ ~8 ꯗꯤꯒ꯭ꯔꯤꯗꯒꯤ ꯌꯥꯝꯅꯥ ꯅꯦꯝꯃꯤ, ꯑꯃꯁꯨꯡ ꯐꯦꯅꯁꯤꯡꯅꯥ ꯃꯄꯨꯡꯐꯥꯅꯥ ꯈꯣꯡꯖꯦꯜ ꯌꯥꯡꯅꯥ ꯆꯦꯅꯕꯥ ꯃꯇꯃꯗꯁꯨ ꯔꯤꯂꯤꯐ ꯇꯧꯕꯥ ꯉꯃꯗꯕꯥ ꯂꯦꯞꯇꯅꯥ ꯑꯋꯥꯡꯕꯥ ꯄ꯭ꯔꯦꯁꯔ ꯂꯩ꯫

 

ꯁꯦꯡꯂꯕꯥ ꯐꯤꯅꯁꯤꯡ ꯑꯗꯨꯕꯨ ꯂꯦꯡꯗꯅꯥ ꯂꯩꯔꯤꯕꯥ ꯍꯥꯏ ꯄ꯭ꯔꯦꯁꯔ ꯑꯃꯁꯨꯡ ꯊꯤꯡꯖꯤꯅꯈ꯭ꯔꯕꯥ ꯃꯇꯨꯡꯗꯥ ꯃꯍꯧꯁꯥꯗꯒꯤ ꯇꯞꯅꯥ ꯇꯞꯅꯥ ꯄ꯭ꯔꯦꯁꯔ ꯍꯟꯊꯔꯀꯄꯥ ꯑꯦꯌꯔ-ꯀꯨꯜ ꯇꯧꯔꯕꯥ ꯀꯟꯗꯦꯟꯁꯔꯁꯤꯡꯒꯤ ꯑꯣꯏꯅꯗꯤ, ꯃꯅꯨꯡꯒꯤ ꯀꯣꯏꯜ ꯕ꯭ꯂꯣꯀꯦꯖ ꯅꯠꯠꯔꯒꯥ ꯄꯥꯔꯁꯤꯑꯦꯜ ꯄꯥꯏꯞ ꯔꯄꯆꯔꯅꯥ ꯏꯐꯦꯛꯇꯤꯚ ꯑꯣꯏꯗꯕꯥ ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖ ꯑꯦꯔꯤꯌꯥ ꯊꯣꯀꯍꯜꯂꯤ꯫

 

ꯁꯤꯅꯛꯔꯣꯟ ꯂꯣ ꯂꯣ ꯄ꯭ꯔꯦꯁꯔ ꯑꯃꯁꯨꯡ ꯀꯨꯂꯤꯡ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯌꯥꯝꯅꯥ ꯍꯟꯊꯔꯀꯄꯒꯥ ꯂꯣꯌꯅꯅꯥ ꯍꯥꯏ ꯄ꯭ꯔꯦꯁꯔꯗꯥ ꯌꯥꯝꯅꯥ ꯍꯟꯊꯕꯥ ꯑꯁꯤꯅꯥ ꯀꯟꯗꯦꯟꯁꯔ ꯄꯔꯐꯣꯔꯦꯁꯟ ꯂꯤꯛ ꯑꯃꯁꯨꯡ ꯑꯆꯧꯕꯥ ꯔꯦꯐ꯭ꯔꯤꯖꯔꯦꯟꯇ ꯂꯣꯁꯀꯤ ꯁꯤꯒꯅꯦꯜ ꯄꯤꯔꯤ꯫

 

 

ꯏꯚꯥꯛꯌꯨꯑꯦꯇꯔꯁꯤꯡꯒꯤ ꯐꯣꯜꯇ ꯃꯑꯣꯡ-ꯃꯇꯧꯁꯤꯡ꯫

Closed-Circuit Cooling Towers: A More Reliable And Universal Cooling Choice For Data Centersꯅꯣꯔꯃꯦꯜ ꯏꯚꯥꯛꯌꯨꯑꯦꯇꯔ ꯀꯣꯏꯜ ꯑꯃꯥ ꯇꯔꯨ-ꯇꯅꯥꯅꯕꯥ ꯐ꯭ꯔꯣꯁ꯭ꯠ ꯑꯃꯅꯥ ꯀꯨꯄꯁꯤꯅꯒꯗꯕꯅꯤ꯫ ꯑꯇꯣꯞꯄꯥ ꯃꯐꯃꯁꯤꯡꯗꯥ ꯐ꯭ꯔꯣꯁ꯭ꯠ-ꯐ꯭ꯔꯤ ꯑꯦꯔꯤꯌꯥꯁꯤꯡꯒꯥ ꯂꯣꯌꯅꯅꯥ ꯂꯣꯀꯦꯜ ꯊꯤꯛ ꯑꯥꯏꯁꯅꯥ ꯃꯅꯨꯡꯒꯤ ꯄꯥꯏꯄꯂꯥꯏꯟ ꯕ꯭ꯂꯣꯀꯦꯖ ꯂꯩ ꯍꯥꯌꯕꯥ ꯇꯥꯀꯏ꯫ ꯌꯨꯅꯤꯠ ꯄꯨꯝꯕꯒꯤ ꯃꯊꯛꯇꯥ ꯑꯀꯅꯕꯥ ꯐ꯭ꯔꯣꯁ꯭ꯇꯤꯡ, ꯅꯣꯔꯃꯦꯜ ꯐꯦꯟ ꯑꯦꯌꯔ ꯚꯣꯜꯌꯨꯝ ꯑꯗꯨꯕꯨ ꯀꯨꯜ-ꯂꯦꯁ ꯑꯥꯎꯇꯂꯦꯠ ꯑꯦꯌꯔ ꯑꯃꯁꯨꯡ ꯌꯥꯝꯅꯥ ꯅꯦꯝꯕꯥ ꯂꯣ ꯄ꯭ꯔꯦꯁꯔꯅꯥ ꯃꯔꯝ ꯑꯣꯏꯗꯨꯅꯥ ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖ ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯌꯥꯝꯅꯥ ꯁꯣꯀꯍꯜꯂꯤ꯫

 

ꯀꯔꯤꯒꯨꯝꯕꯥ ꯏꯚꯥꯛꯌꯨꯑꯦꯇꯔ ꯏꯅꯂꯦꯠ ꯑꯃꯁꯨꯡ ꯑꯥꯎꯇꯂꯦꯇꯀꯤ ꯃꯔꯛꯇꯥ ꯂꯩꯕꯥ ꯑꯦꯌꯔ ꯇꯦꯝꯄꯦꯔꯦꯆꯔꯒꯤ ꯈꯦꯠꯅꯕꯥ ꯑꯗꯨ ꯃꯄꯨꯡꯐꯥꯕꯥ ꯂꯣꯗꯀꯤ ꯃꯈꯥꯗꯥ ꯗꯤꯒ꯭ꯔꯤ 3ꯗꯒꯤ ꯇꯥꯕꯥ ꯑꯣꯏꯔꯕꯗꯤ, ꯏꯚꯥꯛꯌꯨꯑꯦꯇꯔꯒꯤ ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖ ꯐꯉ꯭ꯀꯁꯟ ꯑꯗꯨ ꯁꯣꯌꯗꯅꯥ ꯂꯩꯒꯅꯤ꯫ ꯂꯦꯞꯇꯅꯥ ꯀꯝꯞꯔꯦꯁꯔ ꯑꯣꯚꯔꯂꯣꯗ ꯇꯧꯕꯥ ꯑꯃꯁꯨꯡ ꯆꯥꯡ ꯅꯥꯏꯅꯥ ꯁ꯭ꯇꯥꯔꯠ-ꯑꯞ/ ꯁꯨꯡꯗꯣꯀꯄꯥ ꯑꯁꯤꯁꯨ ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖ ꯀꯝꯄꯣꯅꯦꯟꯇꯁꯤꯡꯅꯥ ꯁꯣꯀꯍꯜꯂꯕꯥ ꯑꯦꯕꯅꯣꯔꯃꯦꯜ ꯂꯣꯗꯁꯤꯡꯗꯒꯤ ꯂꯥꯀꯏ꯫

 

 

III. ꯑꯀꯛꯅꯕꯥ ꯂꯤꯀꯦꯖ ꯗꯦꯃꯦꯖ ꯚꯦꯔꯤꯐꯤꯀꯦꯁꯅꯒꯤꯗꯃꯛ ꯁꯦꯛꯁꯟ ꯄ꯭ꯔꯦꯁꯔ ꯇꯦꯁ꯭ꯠ꯫

 

 

Which Is Better, Open-Loop Or Closed-Loop Cooling Tower?ꯚꯤꯖꯨꯑꯦꯜ ꯏꯟꯁꯄꯦꯛꯁꯟ ꯑꯃꯁꯨꯡ ꯄꯦꯔꯥꯃꯤꯇꯔ ꯃꯣꯅꯤꯇꯔꯤꯡꯅꯥ ꯃꯃꯥꯡꯒꯤ ꯋꯥꯔꯦꯞ ꯈꯛꯇꯃꯛ ꯄꯤ꯫ ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯑꯃꯁꯨꯡ ꯅ꯭ꯌꯨꯃꯦꯇꯤꯛ ꯁꯦꯛꯁꯟ ꯄ꯭ꯔꯦꯁꯔ ꯇꯦꯁ꯭ꯇꯁꯤꯡ ꯑꯁꯤꯅꯥ ꯄꯔꯐꯣꯔꯦꯁꯟ ꯂꯤꯀꯦꯖ ꯀꯅꯐꯔꯝ ꯇꯧꯅꯕꯥ ꯀꯣꯔ ꯃꯦꯊꯗ ꯑꯣꯏꯅꯥ ꯊꯕꯛ ꯇꯧꯏ, ꯃꯁꯤꯅꯥ ꯖꯣꯏꯟꯇ ꯂꯤꯀꯦꯖ ꯑꯃꯁꯨꯡ ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖꯔꯒꯤ ꯍꯀꯆꯥꯡꯗꯥ ꯑꯃꯥꯡ-ꯑꯇꯥ ꯊꯣꯀꯍꯅꯕꯥ ꯑꯁꯤ ꯃꯄꯨꯡ ꯐꯥꯅꯥ ꯈꯦꯠꯅꯍꯜꯂꯤ꯫

 

ꯀꯟꯗꯦꯟꯁꯔ ꯑꯃꯁꯨꯡ ꯏꯚꯥꯛꯌꯨꯑꯦꯇꯔꯁꯤꯡ ꯑꯁꯤ ꯀꯝꯞꯔꯦꯁꯔꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯦꯛꯁꯄꯥꯟꯁꯟ ꯚꯜꯌꯨꯁꯤꯡꯗꯒꯤ ꯂꯧꯊꯣꯀꯎ, ꯃꯗꯨꯒꯤ ꯃꯇꯨꯡꯗꯥ ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖꯔꯁꯤꯡꯒꯤ ꯃꯊꯛ ꯑꯅꯤꯃꯛ ꯃꯁꯥ ꯃꯊꯟꯇꯥ ꯁꯤꯜ ꯇꯧ꯫ ꯁꯦꯜ- ꯑꯃꯁꯨꯡ-ꯇꯨꯕ ꯋꯥꯇꯔ-ꯀꯨꯜ ꯇꯧꯔꯕꯥ ꯀꯟꯗꯦꯟꯁꯔꯁꯤꯡꯒꯤ ꯁꯦꯜ ꯁꯥꯏꯗꯇꯥ ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯄ꯭ꯔꯦꯁꯔ ꯄꯤꯌꯨ ꯑꯃꯁꯨꯡ ꯔꯦꯐ꯭ꯔꯤꯖꯔꯦꯟꯇ ꯄꯥꯏꯄꯂꯥꯏꯅꯁꯤꯡ ꯌꯦꯡꯁꯤꯟꯅꯕꯥ ꯇꯨꯕ ꯁꯥꯏꯗꯇꯥ ꯄ꯭ꯔꯦꯁꯔ ꯇꯦꯁ꯭ꯠ ꯄꯥꯡꯊꯣꯀꯎ꯫

 

 

What Worries You Most When Buying A Cooling Tower?ꯄꯨꯡ 24ꯒꯤ ꯁ꯭ꯇꯦꯇꯤꯛ ꯁ꯭ꯇꯦꯟꯗꯤꯡꯒꯤ ꯑꯣꯏꯅꯥ 1.6~2.5MPaꯒꯤ ꯁ꯭ꯇꯦꯟꯗꯔꯗ ꯄ꯭ꯔꯦꯁꯔ ꯑꯃꯒꯥ ꯂꯣꯌꯅꯅꯥ ꯄ꯭ꯔꯦꯁꯔ ꯊꯝꯅꯕꯒꯤꯗꯃꯛ ꯑꯦꯌꯔ-ꯀꯨꯜ ꯇꯧꯔꯕꯥ ꯀꯣꯏꯂꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯄ꯭ꯂꯦꯠ ꯏꯚꯥꯛꯌꯨꯑꯦꯇꯔꯁꯤꯡꯗꯥ ꯁꯨꯡꯕꯥ ꯅꯥꯏꯠꯔꯣꯖꯦꯟ ꯆꯥꯔꯖ ꯇꯧ꯫ ꯃꯄꯥꯅꯒꯤ ꯑꯣꯏꯜ ꯁ꯭ꯇꯦꯟ ꯅꯠꯠꯔꯒꯥ ꯋꯦꯜꯗ ꯁꯤꯄꯦꯖ ꯌꯥꯎꯗꯅꯥ ꯃꯌꯦꯛ ꯁꯦꯡꯕꯥ ꯄ꯭ꯔꯦꯁꯔ ꯗ꯭ꯔꯣꯄꯅꯥ ꯑꯄꯤꯀꯄꯥ ꯃꯅꯨꯡꯒꯤ ꯀꯣꯏꯜ ꯄꯔꯐꯣꯔꯦꯁꯅꯁꯤꯡ ꯄ꯭ꯔꯃꯥꯟ ꯇꯧꯏ, ꯃꯈꯣꯌ ꯑꯁꯤ ꯔꯤꯚꯔꯁꯤꯕꯜ ꯀꯝꯄꯣꯅꯦꯟꯇ ꯑꯃꯥꯡ-ꯑꯇꯥꯁꯤꯡꯅꯤ꯫

 

ꯃꯥꯏꯅꯣꯔ ꯂꯤꯀꯦꯖ ꯑꯃꯁꯨꯡ ꯃꯄꯨꯡꯐꯥꯅꯥ ꯑꯃꯥꯡ-ꯑꯇꯥ ꯊꯣꯀꯍꯅꯕꯗꯒꯤ ꯈꯦꯠꯅꯕꯥ ꯊꯃꯒꯗꯕꯅꯤ: ꯇꯞꯅꯥ ꯇꯞꯅꯥ ꯔꯦꯐ꯭ꯔꯤꯖꯔꯦꯟꯇ ꯀꯟꯖ꯭ꯌꯨꯝ ꯇꯧꯕꯒꯥ ꯂꯣꯌꯅꯅꯥ ꯄ꯭ꯔꯦꯁꯔ ꯈꯔꯥ ꯍꯟꯊꯔꯀꯄꯅꯥ ꯃꯥꯏꯛꯔꯣ ꯂꯤꯀꯦꯖꯕꯨ ꯈꯪꯅꯩ; ꯑꯆꯧꯕꯥ ꯔꯦꯐ꯭ꯔꯤꯖꯔꯦꯁꯟ ꯑꯣꯏꯜ ꯑꯥꯎꯠꯐ꯭ꯂꯣꯒꯥ ꯂꯣꯌꯅꯅꯥ ꯌꯥꯝꯅꯥ ꯊꯨꯅꯥ ꯄ꯭ꯔꯦꯁꯔ ꯖꯤꯔꯣꯗꯥ ꯍꯟꯊꯔꯀꯄꯅꯥ ꯑꯆꯧꯕꯥ-ꯑꯦꯔꯤꯌꯥ ꯔꯄꯆꯔ ꯑꯃꯁꯨꯡ ꯈꯨꯗꯛꯀꯤ ꯑꯣꯏꯕꯥ ꯀꯝꯄꯣꯅꯦꯟꯇ ꯁ꯭ꯛꯔꯦꯄꯦꯖ ꯍꯥꯌꯕꯅꯤ꯫

 

ꯁꯥꯄꯣꯟ ꯌꯥꯑꯣꯕꯥ ꯏꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯏꯂꯦꯛꯠꯔꯣꯅꯤꯛ ꯂꯤꯛ ꯗꯤꯇꯦꯛꯇꯔꯁꯤꯡꯒꯥ ꯄꯨꯟꯅꯥ ꯊꯕꯛ ꯇꯧꯃꯤꯟꯅꯧ: ꯀꯣꯏꯜ ꯒꯦꯄꯁꯤꯡꯗꯥ ꯂꯦꯞꯇꯅꯥ ꯕꯕꯂꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯂꯦꯡꯗꯕꯥ ꯗꯤꯇꯦꯛꯇꯔ ꯑꯦꯂꯥꯔꯃꯁꯤꯡꯅꯥ ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖꯔꯒꯤ ꯍꯀꯆꯥꯡ ꯑꯗꯨ ꯁꯣꯀꯍꯜꯂꯀꯄꯥ ꯀꯅꯐꯥꯔꯝ ꯇꯧꯏ꯫

 

 

IV. ꯑꯃꯥꯡ-ꯑꯇꯥ ꯃꯈꯜ ꯑꯅꯤ ꯈꯦꯠꯅꯍꯟꯅꯕꯥ ꯁꯤꯁ꯭ꯇꯦꯝ ꯋꯥꯔꯀꯤꯡ ꯀꯟꯗꯤꯁꯟ ꯆꯥꯡꯗꯝꯅꯕꯥ: ꯕ꯭ꯂꯣꯀꯦꯖ ꯑꯃꯁꯨꯡ ꯔꯄꯆꯔ꯫

 

Closed-circuit Cooling Towers

 

ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖ ꯀꯝꯄꯣꯅꯦꯟꯇꯁꯤꯡꯒꯤ ꯑꯃꯥꯡ-ꯑꯇꯥꯁꯤꯡ ꯑꯁꯤ ꯃꯄꯨꯡꯐꯥꯅꯥ ꯇꯣꯉꯥꯅꯕꯥ ꯐꯣꯜꯇ ꯃꯦꯅꯤꯐꯦꯁ꯭ꯇꯦꯁꯅꯁꯤꯡ ꯂꯩꯕꯥ ꯀꯦꯇꯦꯒꯣꯔꯤ ꯑꯅꯤꯗꯥ ꯈꯥꯌꯗꯣꯀꯏ, ꯃꯈꯣꯌ ꯑꯁꯤ ꯊꯕꯛ ꯇꯧꯕꯒꯤ ꯀꯟꯗꯤꯁꯅꯁꯤꯡꯒꯤ ꯈꯨꯠꯊꯥꯡꯗꯥ ꯊꯨꯅꯥ ꯈꯦꯠꯅꯕꯥ ꯌꯥꯏ꯫

ꯕ꯭ꯂꯣꯀꯦꯖꯒꯤ ꯑꯃꯥꯡ-ꯑꯇꯥ ꯊꯣꯀꯄꯥ꯫

 

 

24 Years Of Dedicated Craftsmanship: Focused On Closed-Circuit Cooling Towersꯄꯥꯏꯄꯂꯥꯏꯟ ꯁ꯭ꯀꯦꯂꯤꯡ, ꯑꯣꯏꯜ ꯁ꯭ꯂꯗ ꯑꯃꯁꯨꯡ ꯏꯝꯞꯌꯨꯔꯤꯇꯤꯁꯤꯡꯅꯥ ꯃꯅꯨꯡꯒꯤ ꯆꯦꯅꯦꯂꯁꯤꯡ ꯊꯤꯡꯏ꯫ ꯔꯦꯐ꯭ꯔꯤꯖꯔꯦꯟꯇ ꯂꯤꯛ ꯂꯩꯇꯕꯥ ꯄ꯭ꯔꯦꯁꯔ ꯍꯣꯜꯗꯤꯡ ꯇꯧꯕꯥ ꯃꯇꯃꯗꯥ ꯄ꯭ꯔꯦꯁꯔ ꯗ꯭ꯔꯣꯞ ꯑꯃꯠꯇꯥ ꯊꯣꯛꯇꯦ, ꯑꯗꯨꯝ ꯑꯣꯏꯅꯃꯛ ꯍꯤꯠ ꯇ꯭ꯔꯥꯟꯁꯐꯔꯒꯤ ꯄꯔꯐꯣꯃꯦꯟꯁ ꯑꯁꯤ ꯌꯥꯝꯅꯥ ꯅꯦꯝꯃꯤ꯫

 

ꯀꯟꯗꯦꯟꯁꯔ ꯕ꯭ꯂꯣꯀꯦꯖꯅꯥ ꯋꯥꯡꯈꯠꯄꯥ ꯍꯥꯏ ꯄ꯭ꯔꯦꯁꯔ ꯊꯣꯀꯍꯜꯂꯤ ꯑꯗꯨꯒꯥ ꯏꯚꯥꯛꯌꯨꯑꯦꯇꯔ ꯕ꯭ꯂꯣꯀꯦꯖꯅꯥ ꯂꯣ ꯂꯣ ꯄ꯭ꯔꯦꯁꯔ ꯊꯣꯀꯍꯜꯂꯤ꯫ ꯀꯔꯤꯒꯨꯝꯕꯥ ꯁꯦꯡꯗꯣꯛꯂꯕꯥ ꯑꯃꯁꯨꯡ ꯁꯦꯡꯗꯣꯛꯂꯕꯥ ꯃꯇꯨꯡꯗꯥ ꯊꯕꯛꯀꯤ ꯐꯤꯚꯝ ꯐꯒꯠꯂꯛꯂꯕꯗꯤ, ꯃꯁꯤ ꯑꯄꯤꯀꯄꯥ ꯕ꯭ꯂꯣꯀꯦꯖꯅꯤ꯫

 

Top 10 Closed Cooling Tower Manufacturers In Pakistan 2026ꯀꯔꯤꯒꯨꯝꯕꯥ ꯇꯦꯝꯄꯦꯔꯦꯆꯔꯒꯤ ꯈꯦꯠꯅꯕꯥ ꯑꯃꯁꯨꯡ ꯄ꯭ꯔꯦꯁꯔ ꯑꯗꯨ ꯍꯟꯖꯤꯟ ꯍꯟꯖꯤꯟ ꯀꯦꯃꯤꯀꯦꯜ ꯀ꯭ꯂꯤꯅꯤꯡ ꯑꯃꯁꯨꯡ ꯍꯥꯏ-ꯄ꯭ꯔꯦꯁꯔ ꯋꯥꯇꯔ ꯐ꯭ꯂꯁ ꯇꯧꯔꯕꯥ ꯃꯇꯨꯡꯗꯥ ꯑꯦꯕꯅꯣꯔꯃꯦꯜ ꯑꯣꯏꯅꯥ ꯂꯩꯔꯕꯗꯤ, ꯑꯆꯧꯕꯥ-ꯑꯦꯔꯤꯌꯥ ꯄꯥꯏꯄꯂꯥꯏꯟ ꯊꯨꯒꯥꯏꯕꯥ ꯅꯠꯠꯔꯒꯥ ꯂꯣꯀꯦꯜ ꯋꯦꯜꯗꯤꯡ ꯕ꯭ꯂꯣꯀꯦꯖꯅꯥ ꯃꯇꯝ ꯆꯨꯞꯄꯒꯤ ꯑꯣꯏꯅꯥ ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖ ꯁꯣꯀꯄꯥ ꯊꯣꯀꯍꯜꯂꯤ ꯑꯃꯁꯨꯡ ꯀꯝꯄꯣꯅꯦꯟꯇ ꯍꯣꯡꯗꯣꯀꯄꯥ ꯑꯁꯤ ꯇꯉꯥꯏꯐꯗꯕꯥ ꯑꯣꯏ꯫

ꯂꯤꯛ ꯑꯣꯏꯕꯥ ꯑꯃꯥꯡ-ꯑꯇꯥ ꯊꯣꯀꯄꯥ꯫

 

 

ꯄ꯭ꯔꯦꯁꯔ ꯇꯦꯁ꯭ꯠ ꯇꯧꯕꯥ ꯃꯇꯃꯗꯥ ꯂꯦꯞꯇꯅꯥ ꯄ꯭ꯔꯦꯁꯔ ꯍꯟꯊꯔꯀꯄꯥ, ꯔꯦꯐ꯭ꯔꯤꯖꯔꯦꯟꯇ ꯔꯤꯐꯤꯜ ꯇꯧꯔꯕꯁꯨ ꯀꯨꯂꯤꯡ ꯀꯦꯄꯥꯁꯤꯇꯤ ꯃꯔꯥꯡ ꯀꯥꯌꯅꯥ ꯂꯩꯇꯕꯥ ꯑꯃꯁꯨꯡ ꯔꯦꯐ꯭ꯔꯤꯖꯔꯦꯁꯟ ꯑꯣꯏꯜ ꯃꯥꯡꯈꯤꯕꯥ ꯑꯁꯤ ꯃꯁꯛ ꯊꯣꯀꯄꯥ ꯈꯨꯗꯃꯁꯤꯡꯅꯤ꯫ ꯑꯄꯤꯀꯄꯥ ꯂꯤꯛ ꯄꯣꯏꯟꯇꯁꯤꯡ ꯑꯁꯤ ꯋꯦꯜꯗꯤꯡ ꯇꯧꯗꯨꯅꯥ ꯔꯤꯄꯦꯌꯥꯔ ꯇꯧꯕꯥ ꯌꯥꯏ; ꯃꯜꯇꯤ-ꯄꯣꯏꯟꯇ ꯀꯣꯔꯣꯁꯤꯟ ꯄꯔꯐꯣꯔꯦꯁꯅꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯆꯧꯕꯥ-ꯑꯦꯔꯤꯌꯥꯗꯥ ꯑꯃꯥꯡ-ꯑꯇꯥ ꯊꯣꯀꯍꯅꯕꯥ ꯐꯤꯟ ꯀꯣꯏꯂꯁꯤꯡꯅꯥ ꯑꯅꯧꯕꯥ ꯏꯛꯌꯨꯏꯄꯃꯦꯟꯇꯀꯤ ꯃꯃꯂꯒꯥ ꯅꯛꯅꯕꯥ ꯔꯤꯄꯦꯌꯔꯒꯤ ꯃꯃꯜ ꯊꯣꯀꯍꯜꯂꯤ, ꯃꯗꯨ ꯔꯤꯄꯦꯌꯥꯔ ꯚꯦꯜꯌꯨ ꯑꯃꯠꯇꯥ ꯂꯩꯇꯕꯥ ꯃꯄꯨꯡꯐꯥꯅꯥ ꯑꯃꯥꯡ-ꯑꯇꯥ ꯑꯣꯏꯅꯥ ꯂꯧꯏ꯫

 

 

ꯂꯣꯏꯁꯤꯟꯕ

 

Closed-circuit Cooling Towers - We Only Make High-efficiency, Energy-saving Ones

ꯑꯄꯨꯅꯕꯥ ꯖꯖꯃꯦꯟꯇ ꯄ꯭ꯔꯣꯁꯤꯗ꯭ꯌꯨꯑꯣꯔ: ꯑꯍꯥꯅꯕꯗꯥ ꯀꯣꯔꯣꯁꯤꯟ, ꯑꯣꯏꯜ ꯁ꯭ꯇꯦꯟ ꯑꯃꯁꯨꯡ ꯗꯤꯐꯣꯔꯃꯦꯁꯟ ꯐꯤꯅꯁꯤꯡꯒꯤꯗꯃꯛ ꯃꯤꯠꯅꯥ ꯎꯕꯥ;

 

ꯃꯗꯨꯒꯤ ꯃꯇꯨꯡꯗꯥ ꯍꯤꯠ ꯇ꯭ꯔꯥꯟꯁꯐꯔ ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯑꯗꯨ ꯌꯦꯡꯁꯤꯟꯅꯕꯥ ꯑꯣꯄꯔꯦꯇꯤꯡ ꯄ꯭ꯔꯦꯁꯔ ꯑꯃꯁꯨꯡ ꯇꯦꯝꯄꯦꯔꯦꯆꯔꯒꯤ ꯈꯦꯠꯅꯕꯥ ꯑꯗꯨ ꯔꯤꯗ ꯇꯧꯅꯕꯥ ꯌꯨꯅꯤꯠ ꯑꯗꯨ ꯍꯧꯒꯗꯕꯅꯤ;

 

ꯑꯔꯣꯏꯕꯗꯥ ꯂꯤꯛ ꯀꯅꯐꯥꯔꯝ ꯇꯧꯅꯕꯥ ꯁꯦꯛꯁꯟ ꯅꯥꯏꯠꯔꯣꯖꯦꯟ/ꯍꯥꯏꯗ꯭ꯔꯣꯂꯤꯛ ꯄ꯭ꯔꯦꯁꯔ ꯇꯦꯁ꯭ꯠ ꯄꯥꯡꯊꯣꯀꯄꯥ꯫ ꯈꯔꯥ ꯁ꯭ꯀꯦꯂꯤꯡ ꯑꯃꯁꯨꯡ ꯃꯥꯏꯅꯣꯔ ꯐꯤꯟ ꯕꯦꯟꯗꯤꯡ ꯑꯁꯤ ꯁꯦꯡꯗꯣꯀꯄꯥ ꯑꯃꯁꯨꯡ ꯁꯦꯡꯗꯣꯀꯄꯒꯤ ꯈꯨꯠꯊꯥꯡꯗꯥ ꯔꯤꯀꯣꯚꯔ ꯇꯧꯕꯥ ꯌꯥꯕꯥ ꯑꯄꯤꯀꯄꯥ ꯐꯂꯁꯤꯡꯅꯤ꯫

 

ꯀꯔꯤꯒꯨꯝꯕꯥ ꯄꯔꯐꯣꯔꯦꯁꯟ ꯂꯤꯛ, ꯑꯆꯧꯕꯥ-ꯑꯦꯔꯤꯌꯥ ꯄꯥꯏꯄꯂꯥꯏꯟ ꯕ꯭ꯂꯣꯀꯦꯖ, ꯕꯜꯖ ꯑꯃꯁꯨꯡ ꯀꯣꯔꯣꯗ ꯇꯧꯔꯕꯥ ꯁꯦꯂꯁꯤꯡ, ꯅꯠꯠꯔꯒꯥ ꯔꯤꯄꯦꯌꯥꯔ ꯁꯣꯜꯌꯨꯁꯟ ꯑꯃꯠꯇꯥ ꯂꯩꯇꯕꯥ ꯔꯦꯠ ꯚꯦꯜꯌꯨꯁꯤꯡꯗꯒꯤ ꯌꯥꯝꯅꯥ ꯂꯥꯞꯅꯥ ꯂꯩꯕꯥ ꯍꯤꯠ ꯇ꯭ꯔꯥꯟꯁꯐꯔ ꯇꯦꯝꯄꯦꯔꯦꯆꯔꯒꯤ ꯈꯦꯠꯅꯕꯥ ꯂꯩꯔꯕꯗꯤ, ꯀꯟꯗꯦꯟꯁꯔ ꯅꯠꯠꯔꯒꯥ ꯏꯚꯥꯛꯌꯨꯑꯦꯇꯔ ꯑꯗꯨ ꯃꯄꯨꯡꯐꯥꯅꯥ ꯃꯥꯡꯈꯤ ꯑꯃꯁꯨꯡ ꯑꯄꯨꯅꯕꯥ ꯑꯣꯏꯅꯥ ꯍꯣꯡꯗꯣꯀꯄꯥ ꯃꯊꯧ ꯇꯥꯏ꯫

ꯏꯅꯛꯕꯥꯔꯤ ꯊꯥꯕꯤꯌꯨ