mniꯂꯣꯜ

ꯂꯚꯓꯧ ꯕꯤꯡꯐꯦꯡꯅꯥ ꯁ꯭ꯃꯦꯂꯇꯤꯡ ꯏꯟꯗꯁ꯭ꯠꯔꯤꯒꯤꯗꯃꯛꯇꯥ ꯑꯈꯟꯅꯕꯥ ꯀ꯭ꯂꯣꯖꯗ ꯀꯨꯂꯤꯡ ꯇꯋꯥꯔ꯫

Feb 27, 2026

ꯄꯥꯎꯖꯦꯜ ꯑꯃꯥ ꯊꯥꯗꯣꯀꯎ

 

Customer Site Installation of Closed-Circuit Cooling Tower

 

 

 

ꯏꯅꯔꯖꯤ ꯌꯥꯝꯅꯥ ꯁꯤꯖꯤꯟꯅꯕꯥ, ꯑꯋꯥꯡꯕꯥ ꯍꯤꯠ ꯗꯤꯁꯤꯞꯂꯤꯟ ꯑꯃꯁꯨꯡ ꯂꯦꯞꯇꯅꯥ ꯄꯨꯊꯣꯀꯄꯒꯤ ꯃꯁꯛ ꯊꯣꯀꯄꯥ ꯏꯟꯗꯁ꯭ꯠꯔꯤ ꯑꯃꯥ ꯑꯣꯏꯅꯥ, ꯁ꯭ꯃꯦꯂꯇꯤꯡ ꯏꯟꯗꯁ꯭ꯠꯔꯤ ꯑꯁꯤꯅꯥ ꯀꯨꯂꯤꯡ ꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡꯒꯤ ꯇꯪꯗꯨ ꯂꯩꯇꯥꯕꯥ, ꯀꯣꯔꯣꯁꯤꯟ ꯔꯦꯁꯤꯁ꯭ꯇꯦꯟꯁ, ꯑꯋꯥꯡꯕꯥ ꯇꯦꯝꯄꯦꯔꯦꯆꯔ ꯔꯦꯁꯤꯁ꯭ꯇꯦꯟꯁ ꯑꯃꯁꯨꯡ ꯙꯨꯞ ꯔꯦꯁꯤꯁ꯭ꯇꯦꯟꯁꯇꯥ ꯌꯥꯝꯅꯥ ꯑꯀꯅꯕꯥ ꯃꯊꯧ ꯇꯥꯕꯁꯤꯡ ꯊꯝꯂꯤ꯫ ꯇ꯭ꯔꯦꯗꯤꯁ꯭ꯅꯦꯜ ꯑꯣꯄꯟ ꯀꯨꯂꯤꯡ ꯇꯋꯥꯔꯁꯤꯡ ꯑꯁꯤ ꯁ꯭ꯀꯦꯂꯤꯡ ꯑꯃꯁꯨꯡ ꯄꯣꯂꯨꯁꯟ ꯊꯣꯀꯍꯜꯂꯤ, ꯏꯁꯤꯡ ꯌꯥꯝꯅꯥ ꯁꯤꯖꯤꯟꯅꯩ, ꯑꯃꯁꯨꯡ ꯆꯥꯡ ꯅꯥꯏꯅꯥ ꯁꯦꯟꯅꯕꯒꯤ ꯃꯊꯧ ꯇꯥꯔꯤ, ꯃꯁꯤꯅꯥ ꯃꯣꯗꯔꯟ ꯁ꯭ꯃꯦꯂꯇꯤꯡ ꯄ꯭ꯔꯗꯛꯁꯟ ꯂꯥꯏꯅꯁꯤꯡꯒꯤ ꯂꯣꯡ-ꯇꯔꯝ ꯁ꯭ꯇꯦꯕꯜ ꯑꯣꯄꯔꯦꯁꯅꯒꯤ ꯃꯊꯧ ꯇꯥꯕꯁꯤꯡ ꯑꯗꯨ ꯐꯪꯍꯅꯕꯗꯥ ꯑꯋꯥꯕꯥ ꯑꯣꯏꯍꯜꯂꯤ꯫ꯃꯁꯤꯗꯥ ꯆꯍꯤ ꯲꯰ ꯍꯦꯟꯅꯥ ꯑꯦꯛꯁꯄꯔꯤꯌꯦꯟꯁ ꯂꯩꯔꯕꯥ...ꯏꯟꯗꯁ꯭ꯠꯔꯤꯌꯦꯜ ꯀꯨꯂꯤꯡ ꯐꯤꯜꯗ, ꯂꯚꯖꯧ ꯕꯤꯡꯐꯦꯡ ꯐ꯭ꯂꯨꯏꯗ ꯏꯛꯕꯤꯄꯃꯦꯟꯇ ꯀꯣꯡ, ꯂꯤꯃꯤꯇꯦꯗꯅꯥ ꯑꯈꯟꯅꯅꯥ ꯀꯁ꯭ꯃꯦꯂꯇꯤꯡ ꯏꯟꯗꯁ꯭ꯠꯔꯤꯗꯥ ꯀꯠꯊꯣꯛꯂꯕꯥ ꯀ꯭ꯂꯣꯖꯗ ꯀꯨꯂꯤꯡ ꯇꯋꯥꯔ꯫. ꯀ꯭ꯂꯣꯖꯗ ꯁꯔꯀꯨꯂꯦꯁꯟ ꯁ꯭ꯠꯔꯀꯆꯔ, ꯍꯦꯅꯒꯠꯂꯕꯥ ꯑꯦꯟꯇꯤ-ꯀꯣꯔꯣꯁꯤꯟ ꯗꯤꯖꯥꯏꯟ ꯑꯃꯁꯨꯡ ꯏꯟꯇꯦꯂꯤꯖꯦꯟꯇ ꯇꯦꯝꯄꯦꯔꯦꯆꯔ ꯀꯟꯠꯔꯣꯜ ꯁꯤꯁ꯭ꯇꯦꯝ ꯌꯥꯑꯣꯕꯥ ꯃꯁꯤꯅꯥ ꯁ꯭ꯇꯤꯜ ꯑꯃꯁꯨꯡ ꯅꯟ-ꯐꯦꯔꯣꯁ ꯁ꯭ꯃꯦꯂꯇꯤꯡ ꯏꯟꯗꯁ꯭ꯠꯔꯤꯁꯤꯡꯗꯥ ꯑꯋꯥꯡꯕꯥ ꯇꯦꯝꯄꯦꯔꯦꯆꯔ, ꯃꯩꯈꯨ ꯆꯦꯟꯗꯕꯥ ꯑꯃꯁꯨꯡ ꯌꯥꯝꯅꯥ ꯀꯣꯔꯣꯁꯤꯚ ꯑꯣꯏꯕꯥ ꯊꯕꯛ ꯇꯧꯕꯒꯤ ꯐꯤꯚꯃꯁꯤꯡꯒꯤꯗꯃꯛ ꯇꯪꯗꯨ ꯂꯩꯇꯥꯕꯥ ꯑꯃꯁꯨꯡ ꯏꯐꯤꯁꯤꯌꯦꯟꯇ ꯀꯨꯂꯤꯡ ꯁꯣꯂꯨꯁꯅꯁꯤꯡ ꯄꯤꯔꯤ꯫

 

 

 

Customer Site Installation of Closed-Circuit Cooling Tower

 

 

 

ꯀ꯭ꯂꯣꯖꯗ ꯀꯨꯂꯤꯡ ꯇꯋꯥꯔ ꯑꯁꯤꯅꯥ . ꯄ꯭ꯔꯣꯁꯦꯁ ꯋꯥꯇꯔ, ꯇꯔꯨ-ꯇꯅꯥꯅꯕꯥ ꯏꯁꯤꯡ ꯅꯠꯠꯔꯒꯥ ꯀꯨꯜ ꯇꯧꯒꯗꯕꯥ ꯗꯤꯃꯤꯅꯦꯔꯦꯂꯥꯏꯖ ꯇꯧꯔꯕꯥ ꯏꯁꯤꯡ ꯑꯁꯤ ꯃꯄꯥꯅꯒꯤ ꯅꯨꯡꯁꯤꯠꯀꯥ ꯍꯀꯊꯦꯡꯅꯅꯥ ꯁꯣꯛꯅ-ꯁꯝꯅꯗꯅꯥ ꯀ꯭ꯂꯣꯖ ꯇꯧꯔꯕꯥ ꯀꯣꯏꯂꯁꯤꯡꯒꯤ ꯃꯅꯨꯡꯗꯥ ꯆꯦꯜꯂꯤ꯫ ꯁ꯭ꯞꯔꯦ ꯋꯥꯇꯔ ꯑꯁꯤ ꯀꯣꯏꯂꯁꯤꯡꯒꯤ ꯃꯄꯥꯟꯗꯥ ꯆꯞ ꯃꯥꯟꯅꯅꯥ ꯌꯦꯟꯊꯣꯀꯏ, ꯑꯃꯁꯨꯡ ꯐꯦꯅꯁꯤꯡꯅꯥ ꯐꯣꯔꯁ ꯚꯦꯟꯇꯤꯂꯦꯁꯟ ꯇꯧꯕꯅꯥ ꯏꯚꯥꯛꯌꯨꯑꯦꯇꯤꯚ ꯑꯃꯁꯨꯡ ꯀꯟꯚꯦꯛꯇꯤꯚ ꯍꯤꯠ ꯇ꯭ꯔꯥꯟꯁꯐꯔꯒꯤ ꯈꯨꯠꯊꯥꯡꯗꯥ ꯍꯤꯠ ꯂꯧꯊꯣꯀꯏ꯫ꯃꯅꯨꯡꯒꯤ ꯁꯔꯛꯌꯨꯂꯦꯁꯅꯒꯤ ꯏꯁꯤꯡ ꯑꯁꯤ ꯁꯦꯡꯅꯥ ꯂꯩ, ꯃꯁꯤꯅꯥ ꯐꯟꯗꯥꯃꯦꯟꯇꯦꯜ ꯑꯣꯏꯅꯥ ꯁꯦꯗꯤꯃꯦꯟꯇ, ꯗꯁ꯭ꯠ ꯑꯃꯁꯨꯡ ꯑꯣꯛꯁꯥꯏꯗ ꯁ꯭ꯀꯦꯜ ꯑꯁꯤ ꯀꯨꯂꯤꯡ ꯁꯔꯛꯌꯨꯏꯠꯇꯥ ꯆꯪꯂꯀꯄꯥ ꯊꯤꯡꯏ꯫ ꯃꯁꯤꯅꯥ ꯑꯣꯛꯁꯤꯖꯦꯟ ꯂꯦꯟꯁ, ꯏꯂꯦꯛꯠꯔꯤꯗ, ꯇ꯭ꯔꯥꯟꯁꯐꯣꯔꯃꯔ, ꯀ꯭ꯔꯤꯁ꯭ꯇꯦꯂꯥꯏꯖꯔ ꯑꯃꯁꯨꯡ ꯐꯔꯅꯤꯆꯔ ꯕꯣꯗꯤꯒꯨꯝꯕꯥ ꯃꯔꯨꯑꯣꯏꯕꯥ ꯈꯨꯠꯂꯥꯌꯁꯤꯡ ꯏꯐꯦꯛꯇꯤꯕ ꯑꯣꯏꯅꯥ ꯉꯥꯀꯊꯣꯀꯏ, ꯄꯥꯏꯄꯂꯥꯏꯟ ꯕ꯭ꯂꯣꯀꯦꯖ, ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖ ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯍꯟꯊꯍꯅꯕꯥ, ꯈꯨꯠꯂꯥꯌꯁꯤꯡ ꯁꯣꯀꯄꯥ ꯑꯃꯁꯨꯡ ꯃꯦꯟꯇꯦꯅꯦꯟꯁꯀꯤꯗꯃꯛꯇꯥ ꯆꯥꯡ ꯅꯥꯏꯅꯥ ꯊꯤꯡꯖꯤꯅꯕꯥ ꯊꯤꯡꯏ꯫

 

 

 

Field Application Display Closed-Circuit Cooling Tower in Operation

 

 

 

ꯁ꯭ꯃꯦꯂꯇꯤꯡ ꯁꯥꯏꯠꯁꯤꯡꯗꯥ ꯑꯀꯅꯕꯥ ꯐꯤꯚꯃꯁꯤꯡꯒꯤ ꯄꯥꯎꯈꯨꯝ ꯑꯣꯏꯅꯥ ꯂꯚꯖꯧ ꯕꯤꯡꯐꯦꯡꯅꯥ ꯃꯆꯥꯀꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯁ꯭ꯠꯔꯀꯆꯔꯗꯥ ꯄꯥꯟꯗꯝ ꯊꯝꯂꯤꯕꯥ ꯍꯦꯅꯒꯠꯍꯅꯈ꯭ꯔꯦ꯫ ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖ ꯀꯣꯏꯂꯁꯤꯡ ꯑꯁꯤ ꯑꯋꯥꯡꯕꯥ ꯊꯥꯛꯀꯤ ꯁ꯭ꯇꯦꯅꯂꯦꯁ ꯁ꯭ꯇꯤꯜ, ꯀꯄꯥꯔ ꯑꯦꯂꯣꯌ ꯅꯠꯠꯔꯒꯥ ꯀꯣꯔꯣꯁꯤꯟ-ꯔꯦꯁꯤꯁ꯭ꯇꯦꯟꯇ ꯑꯦꯂꯣꯌꯅꯥ ꯁꯦꯝꯕꯅꯤ, ꯃꯈꯣꯌ ꯑꯁꯤ ꯑꯋꯥꯡꯕꯥ ꯇꯦꯝꯄꯦꯔꯦꯆꯔ, ꯑꯦꯁꯤꯗ ꯑꯃꯁꯨꯡ ꯑꯂꯀꯥꯂꯤ, ꯑꯃꯁꯨꯡ ꯑꯣꯛꯁꯤꯗꯦꯇꯤꯕ ꯁ꯭ꯃꯣꯛ ꯏꯔꯣꯁꯅꯗꯥ ꯔꯦꯁꯤꯁ꯭ꯇꯦꯟꯇ ꯑꯣꯏ, ꯑꯃꯁꯨꯡ ꯑꯋꯥꯡꯕꯥ ꯇꯦꯝꯄꯦꯔꯦꯆꯔꯗꯥ ꯔꯤꯇꯔꯟ ꯋꯥꯇꯔꯒꯤ ꯏꯝꯄꯦꯛꯇ ꯑꯗꯨ ꯃꯇꯝ ꯁꯥꯡꯅꯥ ꯊꯦꯡꯅꯕꯥ ꯉꯝꯃꯤ꯫ꯏꯛꯕꯤꯄꯃꯦꯟꯇ ꯀꯦꯁꯤꯡ ꯑꯁꯤꯅꯥ ꯑꯀꯅꯕꯥ ꯑꯦꯟꯇꯤ-ꯀꯣꯔꯣꯁꯤꯟ ꯀꯣꯇꯤꯡ ꯅꯠꯠꯔꯒꯥ ꯒ꯭ꯌꯥꯂꯚꯥꯅꯥꯏꯖ ꯇꯧꯔꯕꯥ ꯁ꯭ꯇꯤꯜ ꯄ꯭ꯂꯦꯠ, ꯂꯣꯌꯅꯅꯥ... ꯃꯩꯁꯥ, ꯐ꯭ꯂꯨ ꯒ꯭ꯌꯥꯁ ꯑꯃꯁꯨꯡ ꯋꯥꯇꯔ ꯚꯦꯄꯣꯔ ꯂꯥꯀꯁꯤꯟꯅꯕꯥ ꯃꯔꯨꯑꯣꯏꯕꯥ ꯁꯔꯨꯀꯁꯤꯡꯗꯥ ꯁꯤꯂꯤꯡ ꯍꯦꯅꯒꯠꯍꯅꯕꯥ꯫ ꯐꯦꯅꯁꯤꯡ, ꯁ꯭ꯞꯔꯦ ꯁꯤꯁ꯭ꯇꯦꯃꯁꯤꯡ, ꯏꯁꯤꯡ ꯈꯣꯃꯖꯤꯅꯕꯥ ꯇꯦꯉ꯭ꯀꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯇꯣꯞꯄꯥ ꯀꯝꯄꯣꯅꯦꯟꯇꯁꯤꯡ ꯑꯁꯤ ꯙꯨꯞ ꯑꯃꯁꯨꯡ ꯀꯣꯔꯣꯁꯤꯟ ꯉꯥꯀꯊꯣꯛꯅꯕꯥ ꯇ꯭ꯔꯤꯠ ꯇꯧꯏ, ꯃꯁꯤꯅꯥ ꯲꯴/꯷ ꯂꯦꯞꯇꯅꯥ ꯍꯦꯚꯤ-ꯗ꯭ꯌꯨꯇꯤ ꯑꯣꯄꯔꯦꯁꯟꯗꯥ ꯑꯦꯗꯞꯇꯦꯠ ꯇꯧꯏ꯫ꯇ꯭ꯔꯦꯗꯤꯁ꯭ꯅꯦꯜ ꯑꯣꯄꯟ ꯀꯨꯂꯤꯡ ꯇꯋꯥꯔꯁꯤꯡꯒꯥ ꯆꯥꯡꯗꯝꯅꯕꯗꯥ, ꯏꯛꯕꯤꯄꯃꯦꯟꯇ ꯑꯁꯤꯅꯥ ꯁ꯭ꯀꯦꯂꯤꯡ ꯔꯤꯁ꯭ꯛ ꯅꯦꯝꯕꯥ, ꯂꯦꯡꯗꯕꯥ ꯍꯤꯠ ꯑꯦꯛꯁꯆꯦꯟꯖ ꯏꯐꯤꯁꯤꯑꯦꯟꯁꯤ ꯑꯃꯁꯨꯡ ꯇꯦꯝꯄꯦꯔꯦꯆꯔ ꯀꯟꯠꯔꯣꯜ ꯑꯦꯛꯌꯨꯔꯦꯁꯤ ±1 ꯗꯤꯒ꯭ꯔꯤ ꯐꯥꯑꯣꯕꯥ ꯌꯥꯑꯣꯏ, ꯃꯁꯤꯅꯥ ꯁ꯭ꯃꯦꯂꯇꯤꯡ ꯄ꯭ꯔꯣꯁꯦꯁꯁꯤꯡꯒꯤ ꯑꯀꯅꯕꯥ ꯂꯦꯞꯄꯥ ꯂꯩꯇꯕꯥ ꯇꯦꯝꯄꯦꯔꯦꯆꯔ ꯑꯃꯁꯨꯡ ꯄ꯭ꯔꯦꯁꯔꯒꯤ ꯃꯊꯧ ꯇꯥꯕꯁꯤꯡ ꯑꯗꯨ ꯐꯪꯍꯜꯂꯤ꯫

 

 

 

 

Customer Site Installation of Closed-Circuit Cooling Tower

 

 

 

 

ꯏꯅꯔꯖꯤ ꯁꯦꯚꯤꯡ ꯑꯃꯁꯨꯡ ꯑꯀꯣꯌꯕꯒꯤ ꯐꯤꯕꯝ ꯉꯥꯛ-ꯁꯦꯅꯕꯒꯤ ꯃꯇꯥꯡꯗꯥ, ꯂꯧꯎ-ꯁꯤꯡꯎꯒꯤ ꯂꯃꯗꯥ ꯂꯚꯖꯧ ꯕꯤꯡꯐꯦꯡꯒꯤ ꯊꯣꯡ ꯂꯣꯜꯂꯕꯥ ꯀꯨꯂꯤꯡ ꯇꯋꯥꯔ ꯑꯁꯤꯅꯥ ꯊꯣꯏꯗꯣꯛ ꯍꯦꯟꯗꯣꯀꯄꯥ ꯀꯥꯟꯅꯕꯥ ꯀꯌꯥ ꯂꯩꯔꯤ꯫ ꯏꯟꯇꯔꯅꯦꯜ ꯁꯔꯀꯨꯂꯦꯁꯟ ꯁꯤꯁ꯭ꯇꯦꯝ ꯑꯁꯤꯅꯥ ꯆꯥꯎꯔꯥꯛꯅꯥ ꯏꯁꯤꯡ ꯄꯣꯂꯨꯁꯟ ꯑꯃꯠꯇꯥ ꯄꯨꯊꯣꯛꯇꯦ, ꯃꯁꯤꯗꯥ ꯷꯰%ꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯏꯁꯤꯡ ꯁꯦꯚꯤꯡ ꯇꯧꯕꯒꯤ ꯆꯥꯡ ꯂꯩ, ꯃꯁꯤꯅꯥ ꯏꯁꯤꯡ ꯔꯤꯞꯂꯦꯅꯤꯡ ꯑꯃꯁꯨꯡ ꯗꯤꯁꯆꯥꯔꯖ ꯇꯧꯕꯥ ꯑꯁꯤ ꯌꯥꯝꯅꯥ ꯍꯟꯊꯍꯜꯂꯤ, ꯃꯁꯤꯅꯥ ꯁ꯭ꯃꯦꯂꯇꯤꯡ ꯏꯟꯗꯁ꯭ꯠꯔꯤꯒꯤ ꯏꯅꯔꯖꯤ ꯀꯟꯖꯔꯕꯦꯁꯟ, ꯀꯟꯖꯨꯃꯁꯟ ꯍꯟꯊꯍꯅꯕꯥ ꯑꯃꯁꯨꯡ ꯑꯀꯣꯌꯕꯒꯤ ꯐꯤꯕꯝ ꯉꯥꯛ-ꯁꯦꯅꯕꯒꯤ ꯄꯣꯂꯤꯁꯤꯁꯤꯡꯒꯥ ꯃꯥꯟꯅꯩ꯫ ꯑꯦꯝꯕꯤꯑꯦꯟꯇ ꯇꯦꯝꯄꯦꯔꯦꯆꯔ, ꯐꯦꯅꯁꯤꯡ ꯑꯃꯁꯨꯡ ꯋꯥꯇꯔ ꯄꯝꯄꯁꯤꯡꯒꯤ ꯏꯅꯔꯖꯤ ꯁꯤꯖꯤꯟꯅꯕꯥ ꯍꯟꯊꯍꯜꯂꯤ꯫ꯃꯁꯤꯒꯤ ꯃꯅꯨꯡꯗꯥ, ꯀ꯭ꯂꯣꯖꯗ ꯑꯣꯄꯔꯦꯁꯅꯅꯥ ꯏꯁꯤꯡ ꯇꯨꯡꯁꯤꯅꯕꯥ ꯑꯃꯁꯨꯡ ꯅꯣꯡꯂꯩ-ꯅꯨꯡꯁꯤꯠ ꯁꯟꯗꯣꯀꯄꯥ ꯍꯟꯊꯍꯜꯂꯤ, ꯃꯐꯝ ꯑꯗꯨꯗꯥ ꯊꯕꯛ ꯇꯧꯕꯒꯤ ꯑꯀꯣꯌꯕꯒꯤ ꯐꯤꯕꯝ ꯐꯒꯠꯍꯜꯂꯤ, ꯑꯃꯁꯨꯡ ꯑꯀꯣꯌꯕꯒꯤ ꯐꯤꯕꯝ ꯉꯥꯀꯊꯣꯀꯄꯥ ꯑꯃꯁꯨꯡ ꯁꯥꯐꯕꯥ ꯄꯨꯊꯣꯀꯄꯒꯤ ꯁ꯭ꯇꯦꯟꯗꯔꯗ ꯑꯅꯤ ꯉꯥꯛꯂꯤ꯫

 

 

 

 

A Closed Circuit Cooling Tower Cools Down EquipmentDetailed Cooling Process Of Oasis Bingfeng Counterflow Closed-Circuit Cooling Tower

 

 

 

ꯃꯁꯤꯒꯤ ꯄꯣꯠꯊꯣꯛ ꯑꯁꯤ ꯕ꯭ꯂꯥꯁ꯭ꯠ ꯐꯔꯅꯦꯁ, ꯀꯟꯚꯥꯔꯇꯔ, ꯏꯂꯦꯛꯠꯔꯤꯛ ꯑꯥꯔꯛ ꯐꯔꯅꯦꯁ, ꯂꯦꯞꯇꯅꯥ ꯀꯥꯁ꯭ꯇꯤꯡ, ꯔꯣꯂꯤꯡ, ꯑꯦꯂꯨꯃꯤꯅꯤꯌꯝ ꯏꯂꯦꯛꯠꯔꯣꯂꯥꯏꯁꯤꯁ ꯑꯃꯁꯨꯡ ꯀꯣꯄꯥꯔ ꯁ꯭ꯃꯦꯂꯇꯤꯡꯒꯨꯝꯕꯥ ꯃꯔꯨꯑꯣꯏꯕꯥ ꯊꯧꯑꯣꯡꯁꯤꯡꯗꯥ ꯄꯥꯛ ꯁꯟꯅꯥ ꯁꯤꯖꯤꯟꯅꯩ, ꯃꯁꯤꯅꯥ ꯖꯤꯖꯤꯟ ꯀꯄꯥꯔ, ꯖꯤꯌꯥꯅꯂꯣꯡ ꯁ꯭ꯇꯤꯜ ꯑꯃꯁꯨꯡ ꯑꯦꯝ.ꯁꯤ.ꯁꯤ ꯏꯛꯕꯤꯄꯃꯦꯟꯇ ꯈꯨꯗꯤꯡꯃꯛꯀꯤ ꯂꯣꯡ ꯁꯔꯚꯤꯁ ꯂꯥꯏꯐ, ꯐꯦꯏꯂꯔ ꯔꯦꯠ ꯑꯃꯁꯨꯡ ꯃꯦꯟꯇꯦꯅꯦꯟꯁꯀꯤ ꯃꯃꯜ ꯌꯥꯝꯅꯥ ꯍꯟꯊꯍꯅꯕꯥ, ꯑꯃꯁꯨꯡ ꯁ꯭ꯃꯦꯂꯇꯤꯡ ꯄ꯭ꯔꯗꯛꯁꯟ ꯂꯥꯏꯅꯁꯤꯡꯒꯤ ꯏꯐꯤꯁꯤꯌꯦꯟꯇ ꯑꯣꯄꯔꯦꯁꯟꯗꯥ ꯃꯇꯦꯡ ꯄꯥꯡꯕꯥ꯫

 

 

 

Oasis Bingfeng Closed Circuit Cooling Tower

 

 

 

ꯇꯦꯛꯅꯣꯂꯣꯖꯤꯒꯤ ꯑꯅꯧꯕꯥ ꯊꯧꯑꯣꯡꯁꯤꯡ ꯑꯁꯤ ꯃꯔꯨ ꯑꯣꯏꯅꯥ ꯂꯧꯗꯨꯅꯥ ꯑꯃꯁꯨꯡ ꯁꯄꯣꯔꯠ ꯑꯣꯏꯅꯥ ꯀꯁ꯭ꯇꯃꯁ ꯑꯣꯏꯕꯥ ꯁꯔꯕꯤꯁꯁꯤꯡ ꯂꯧꯗꯨꯅꯥ, ꯂꯚꯖꯧ ꯕꯤꯡꯐꯦꯡ ꯐ꯭ꯂꯨꯏꯗ ꯏꯛꯕꯤꯄꯃꯦꯟꯇ ꯀꯣ., ꯂꯤꯃꯤꯇꯦꯗꯅꯥ ꯂꯦꯞꯇꯅꯥ ꯁ꯭ꯃꯦꯂꯇꯤꯡ ꯏꯟꯗꯁ꯭ꯠꯔꯤꯒꯤꯗꯃꯛꯇꯥ ꯑꯋꯥꯡꯕꯥ ꯊꯥꯛꯀꯤ, ꯌꯥꯝꯅꯥ ꯊꯥꯖꯕꯥ ꯌꯥꯕꯥ ꯑꯃꯁꯨꯡ ꯏꯅꯔꯖꯤ ꯁꯦꯚꯤꯡ ꯇꯧꯕꯥ ꯀꯨꯂꯤꯡ ꯏꯛꯕꯤꯄꯃꯦꯟꯇꯁꯤꯡ ꯄꯤꯔꯤ꯫ ꯁ꯭ꯃꯦꯂꯇꯤꯡ ꯑꯁꯤ ꯇ꯭ꯔꯦꯗꯤꯁ꯭ꯅꯦꯜ ꯑꯣꯄꯟ ꯀꯨꯂꯤꯡ ꯏꯛꯕꯤꯄꯃꯦꯟꯇꯁꯤꯡꯗꯒꯤ ꯍꯦꯟꯅꯥ ꯄꯥꯝꯅꯕꯥ ꯑꯂꯇꯔꯅꯦꯇꯤꯕ ꯑꯣꯏꯔꯒꯅꯤ, ꯃꯁꯤꯅꯥ ꯃꯣꯗꯔꯟ ꯃꯦꯇꯥꯂꯔꯖꯤ ꯑꯃꯁꯨꯡ ꯅꯟ-ꯐꯦꯔꯣꯁ ꯁ꯭ꯃꯦꯂꯇꯤꯡꯒꯤ ꯑꯋꯥꯡꯕꯥ ꯊꯥꯛꯀꯤ ꯗꯤꯕꯦꯂꯄꯃꯦꯟꯇꯀꯤꯗꯃꯛ ꯑꯀꯅꯕꯥ ꯁꯄꯣꯔꯠ ꯄꯤꯒꯅꯤ꯫

ꯏꯅꯛꯕꯥꯔꯤ ꯊꯥꯕꯤꯌꯨ